Turbo Wood Lathes FAQ: Troubleshooting Vibration or Noise After Spindle & Bearing Installation
Created by Gabriel Izzo, Modified on Thu, 18 Jun at 4:32 PM by Gabriel Izzo
If the spindle was disassembled and reinstalled and afterwards there is increased noise or vibration, there are a few possible causes to investigate. This guide walks through the most common causes and the measurement checks used to diagnose them.
The motor and spindle pulleys may not be perfectly aligned vertically after reassembly. Even slight vertical misalignment can create additional vibration and belt noise during operation.
The bearing side shields may have been slightly dented or damaged during removal and reinstallation. If the brass seals are rubbing against the bearing components, this can produce friction noise and additional vibration.
The most common cause of vibration after reassembly is handwheel runout. If the handwheel was reinstalled unevenly or tightened without monitoring runout with a dial indicator, it can become slightly skewed and create a rotating imbalance. If the vibration is more pronounced at certain speeds, this is characteristic of harmonic vibration caused by a rotating imbalance.
The spindle bearings used in the T-60S are quite large, with ball elements nearly the size of marbles. Because of this, some intermittent noise that sounds like marbles rolling over each other can be normal and may be unavoidable even when everything is assembled correctly. A failed bearing on the T-60S will typically produce a very loud, consistent knocking noise — if the noise is intermittent rather than constant, a major bearing failure is unlikely.
The following are the spindle inspection standards used during factory testing. Use these as your pass/fail reference for the measurements recorded in Checks 1 and 2.
| Inspection Item | Maximum Tolerance |
|---|---|
| Spindle radial runout | 0.01 mm (0.0004") |
| Spindle end-face runout | 0.01 mm (0.0004") |

Mount the magnetic dial indicator securely to the lathe bed and position the indicator tip against the spindle's outside diameter.

Move the indicator so the tip contacts the spindle shoulder face.

Mount the dial indicator to the top of the headstock and position the indicator tip against the handwheel face.
If the handwheel screws are not tightened carefully, they can introduce runout and cause additional vibration and bearing stress. Use the following technique:

For further assistance diagnosing spindle vibration or noise, please contact our support team or call 888-211-0397.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article