Alpha HW110LC Table Saw: Power Requirements

Created by Gabriel Izzo, Modified on Thu, 11 Apr 2024 at 12:26 PM by Gabriel Izzo

The Harvey Alpha HW110LC table saw is configured from the factory with a NEMA 5-20P plug and a 125v switch but there is also an optional 230v switch included with the HW110LC that can be used to rewire the saw for single phase 230v-20A power supply. 


If configuring the saw for 230v-20A power, the plug end will need to be changed to NEMA 6-20P along with the receptacle which will need to be changed to NEMA 6-20R and the breaker in the electrical panel that corresponds to the outlet will need to be a 240v, 20A, double-pole breaker.


For more information on the rewiring instructions for the HW110LC please see the following solution article:

How-to: Setting up the Alpha HW110LC-36(P) table saw for 230v instead of the default 115v configuration

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article