On the HW110LC, the cast iron table is cabinet-mounted, meaning the main portion of the table is secured directly to the cabinet using four cap screws (M10-1.5 x 25mm).
In addition to these mounting bolts, there are two set screws located diagonally at the front left and rear right corners, positioned next to the mounting bolts and typically concealed beneath the flat washers. These set screws are installed at the factory to prevent the table from shifting during shipping.
Important:
These set screws must be completely removed before attempting any alignment adjustments to the cast iron table. As long as they remain in place, they will lock the table in position and prevent any movement.
Once removed, the set screws should be discarded, as they are intended for shipping stability only and will not realign properly if reused.
Here is a video demonstrating this: Video Link
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article