Alpha HW110LC Table Saw: Power Requirements

Created by Gabriel Izzo, Modified on Thu, 11 Apr at 12:26 PM by Gabriel Izzo

The Harvey Alpha HW110LC table saw is configured from the factory with a NEMA 5-20P plug and a 125v switch but there is also an optional 230v switch included with the HW110LC that can be used to rewire the saw for single phase 230v-20A power supply. 


If configuring the saw for 230v-20A power, the plug end will need to be changed to NEMA 6-20P along with the receptacle which will need to be changed to NEMA 6-20R and the breaker in the electrical panel that corresponds to the outlet will need to be a 240v, 20A, double-pole breaker.


For more information on the rewiring instructions for the HW110LC please see the following solution article:

How-to: Setting up the Alpha HW110LC-36(P) table saw for 230v instead of the default 115v configuration