Gyro Air G-700: All Parameters Reset - Siemens Inverter Only

Created by Gabriel Izzo, Modified on Tue, 19 May at 2:03 PM by Gabriel Izzo

Gyro Air G-700 · VFD / Inverter
All Parameters Reset — Siemens Sinamics V20 Inverter Only
Applicable Model
Gyro Air G-700 — Siemens V20 Inverter Models Only
!
This guide applies to Siemens V20 inverter models only

Do not use this guide on G-700 models with an Inovance inverter. Check below to confirm which inverter your unit has before proceeding.

High Voltage Electrical Safety Warning
+
The unit must remain connected to power to perform a VFD parameter reset. This procedure is performed while the electrical box is live.
+
Only interact with the VFD control screen and buttons. Do not touch any wiring, terminals, bus bars, or other electrical components inside the box at any time during this procedure.
+
Open the electrical box, perform the reset using only the control buttons, then close the box. Nothing else inside the box should be touched, adjusted, or disturbed.
+
Wear insulated gloves and safety glasses when the electrical box is open, even if you are only pressing buttons.
+
Ensure the work area is dry and free of conductive materials. Never work on or near open electrical components in damp or wet conditions.
i
If you are not comfortable performing this procedure with the unit live, contact our support team or a qualified electrician before proceeding. Harvey Industries is not liable for injury or damage resulting from improper handling of live electrical components.
Step 1 — Identify Your Inverter Model

Check the front control panel of your G-700 to determine which inverter model you have:

✓ Siemens V20 Inverter

Front panel is labeled SIEMENS at the top of the screen above the readout, and has a Hand Symbol button.

Siemens V20 Control Panel Fig. 1
Siemens V20 inverter control panel showing SIEMENS label and Hand Symbol button
× Inovance Inverter — Not This Guide

Front panel does not have the Hand Symbol button and is not labeled Siemens. Use the Inovance guide instead.

Inovance Inverter Control Panel Fig. 2
Inovance inverter control panel without Hand Symbol button or Siemens label
 Inovance MD200 Series AC Drive User Guide  
Step 2 — Perform the Parameters Reset

Follow these steps to reset the Siemens Sinamics V20 inverter parameters:

1
Set P0003 to 1 first to enable basic parameter access.
2
If the reset does not work, restore factory settings by setting the parameters to the values shown in the diagram below.
When setting parameter P0724, ensure P0003 is set to '3' first so that the full list of parameters becomes accessible. With P0003 set to '1' from the reset, P0724 may not be listed.
Factory Reset Parameter Settings Fig. 3
Siemens V20 factory reset parameter settings table
Inverter Reset — Menu Flow Diagram Fig. 4
Siemens V20 inverter reset menu flow diagram
i

For technical assistance, please contact our support team.